Farm solar · Northern Ireland

Farm solar built around your sheds

Three-phase systems on shed roofs, sized to milking, cooling, drying and ventilation loads.

028 9099 1221

Rather talk it through? Call us first

A farm shed roof covered with solar panels

Roofs

shed roofs, surveyed first

NIE Networks

G99/NI, rural capacity checkedS21

Inverters

EcoFlow OCEAN 2 Three-Phase 5 to 15 kW, or PowerOcean Plus up to 29.9 kW / 180 kWhS5S4

Coming soon

Eleven Celtic Sea 12 kW, up to 48 kWS15

Funding

no farm solar grant open today

What you get

Designed for how a farm uses power

Roof survey first

We check asbestos sheeting and purlin strength before anything else.

Rural grid checked early

We look at local network capacity with NIE Networks before we design.S21

Storage for cold sheds (coming soon)

Eleven Energy sodium-ion, coming soon, charges down to minus 20°C, so it will suit outbuildings through the winter.S11

EcoFlow PowerOcean Plus battery bank on a commercial building

Funding

Paying for it

No NI capital grant for farm solar is open today, and DAERA’s latest scheme did not include solar.S33 So we design for payback on your own use. Farm businesses can use the Annual Investment Allowance.S31

All NI grants →

Worked examples

What a system could cost and save

Two example systems, worked out from published figures. They are examples, not customers. Your free survey gives your own figures.

Worked example

Farm A: 91 panels (40.04 kW) on a dairy shed

A dairy producing 1.5 million litres a year, using about 63,500 kWhS59.

System

91 × 440 W panels, 40.04 kW, three-phase

Cost

£48,208, no grant counted

Makes

32,623 kWh a year

First-year saving

£3,938 to £6,300

Payback

7.7 to 12.2 years

Payback counts savings on your bill only, not export payments. We confirm at your survey whether export payments apply to yours.

Farm businesses may qualify for the NISEP business grant; we check this at survey.

How we worked this out
  • Cost: 40.04 kW × £1,204 per kW, the 2025-26 median for 10 to 50 kWS42S43, excluding VAT
  • Farm use: 1,500,000 litres × 42.34 Wh per litreS59. 62% of dairy use falls between 9am and midnightS59. East-west sheds may make less: your survey checks your roof.
  • Output: 40.04 kW × 823 kWh per kW a year, the measured average for all NI solar in 2025S40, less 1% first-year wearS60 = 32,623 kWh
  • Used on the farm: shown as 50% to 80% (16,312 to 26,098 kWh). Saves £3,938 to £6,300 at 24.14p, the UK business averageS51. Small businesses often pay moreS52, which shortens payback.
  • Exported: 16,311 to 6,525 kWh. Not counted: export payments are left out of these figures.
  • Simple payback: £48,208 ÷ £6,300 = 7.7 years, to £48,208 ÷ £3,938 = 12.2 years. No grant counted. Capital allowancesS31 are not included.

Worked example

Farm B: 113 panels (49.72 kW) on a larger dairy

A dairy producing 3 million litres a year, using about 127,000 kWhS59, with milking, cooling and water heating through the day.

System

113 × 440 W panels, 49.72 kW, three-phase

Cost

£59,863, no grant counted

Makes

40,510 kWh a year

First-year saving

£6,845 to £8,801

Payback

6.8 to 8.7 years

Payback counts savings on your bill only, not export payments. We confirm at your survey whether export payments apply to yours.

Farm businesses may qualify for the NISEP business grant; we check this at survey.

How we worked this out
  • Cost: 49.72 kW × £1,204 per kW, the 2025-26 median for 10 to 50 kWS42S43, excluding VAT
  • Farm use: 3,000,000 litres × 42.34 Wh per litreS59. The system makes about a third of that, and 62% of dairy use falls between 9am and midnightS59, so more of it is used on the farm than on Farm A. Sized just under 50 kW so the Power NI export price appliesS50. Three-phase, approved under G99/NI firstS21.
  • Output: 49.72 kW × 823 kWh per kW a year, the measured average for all NI solar in 2025S40, less 1% first-year wearS60 = 40,510 kWh
  • Used on the farm: shown as 70% to 90% (28,357 to 36,459 kWh). Saves £6,845 to £8,801 at 24.14p, the UK business averageS51. Small businesses often pay moreS52, which shortens payback.
  • Exported: 12,153 to 4,051 kWh. Not counted: export payments are left out of these figures.
  • Simple payback: £59,863 ÷ £8,801 = 6.8 years, to £59,863 ÷ £6,845 = 8.7 years. No grant counted. Capital allowancesS31 are not included.

See all seven examples and how we work them out → · Get my free quote →

Questions from farmers

Farm solar questions

My farm runs on three-phase. Can you help?

Yes. Most farms with milking, cooling or drying loads are on three-phase, and farm systems are usually much larger than a home system. We survey your shed roofs first, size the system to your daytime load, and handle the G99/NI approval with NIE Networks before we install.S21 See the farm solar worked examples.

Will it work in a power cut?

It can. EcoFlow PowerOcean Plus can keep chosen loads on your farm running in a power cut, with conditions we check at survey. Eleven Energy, coming soon once it is certified in Northern Ireland, will back up chosen essential circuits.S4S12 Tell us what matters to you at survey and we’ll design for it.

Quick enquiry

Want us to call you?

Leave a few details and we’ll ring to talk it through, or answer five quick questions for a fuller quote.

BRISK Solar is part of BRISK Technology.

One partner for your solar and batteries, IT, Wi-Fi and networks, broadband, phones, CCTV, websites, card payments and EPOS systems, so there’s one number to call whatever you need.